WSA-Tuned Fractional TD–TI Controller with Vehicle-to-Grid Support for Enhanced Frequency Regulation in Renewable-Based Microgrids

  • VŠB – Technical University of Ostrava
  • Applied Science Private University
  • Aswan University

Research output: Contribution to journal › Article › peer-review

Abstract

High penetration of photovoltaic and wind generation exposes low-inertia microgrids to frequency excursions, while vehicle-to-grid (V2G) support is constrained by owner participation, converter limits, and communication quality. This study evaluates an integrated framework combining a fractional tilted-derivative–tilted-integral (TD–TI) controller, offline wave search algorithm (WSA) tuning, diesel-generator regulation, and bounded active-power support from aggregated plug-in electric vehicles. WSA minimizes the integral of time-weighted absolute frequency error (ITAE), and the optimized parameters remain fixed throughout the robustness tests. MATLAB/Simulink studies cover step-load, multi-step and random load changes, renewable intermittency, voluntary PEV participation, V2G command delay and interruption, and ±20%/±40% parameter uncertainty. Under the step-load test, the complete TD–TI + WSA + V2G configuration achieves a maximum frequency deviation of 0.130 Hz, a settling time of 10.4 s, and ITAE of 0.410, representing reductions of 62.9%, 62.2%, and 59.0%, respectively, relative to PID. Under multi-step and random loading, the corresponding reductions reach 81.0%, 72.7%, and 65.0%. Renewable intermittency is regulated with a 0.005 Hz peak deviation, 4.8 s settling time, and ITAE of 0.290. Complete PEV opt-out retains regulation through the independent TD–TI/diesel path, whereas V2G participation improves the transient response. Severe communication impairment progressively degrades performance, while the tested one-at-a-time parameter perturbations remain bounded. Thus, the contribution lies in the coordinated integration and validation framework—not a new TD–TI topology, and V2G serves as a fast supplementary resource rather than a prerequisite for closed-loop regulation.

Original languageEnglish
Article numbere03622
JournalScientific African
Volume34
DOIs
StatePublished - Dec 2026

UN SDGs

This output contributes to the following UN Sustainable Development Goals (SDGs)

  1. SDG 7 - Affordable and Clean Energy
    SDG 7 Affordable and Clean Energy

Keywords

  • Fractional TD–TI controller
  • Frequency stability
  • Renewable-based microgrids
  • Vehicle-to-grid
  • Wave search algorithm

Fingerprint

Dive into the research topics of 'WSA-Tuned Fractional TD–TI Controller with Vehicle-to-Grid Support for Enhanced Frequency Regulation in Renewable-Based Microgrids'. Together they form a unique fingerprint.

Cite this