TY - JOUR
T1 - Novel blocking based protection for 220 kV closed-loop underground cable using moving window averaging directional relay
AU - Mourad, Dina
N1 - Publisher Copyright:
© 2019 Praise Worthy Prize S.r.l.-All rights reserved.
PY - 2019/1/1
Y1 - 2019/1/1
N2 - A paradigm shift in the philosophy of protection occurs due to distributed generation presence. To adopt the renewable energy generation and enhance supply reliability, a closed-loop operation mode has been involved. The conventional protection cannot adopt the distributed generation since faults have become bidirectional. This paper introduces an ultra-high-speed blocking based on pilot protection system for closed-loop underground cable networks. The proposed protection system uses directional relays based on a suggested averaging window technique and remote terminal units, RTUs, in the automation system. Selection and isolation of the fault zone can be obtained by the neighboring RTUs collaboration. RTUs can automatically be synchronized after fault triggering and don’t require further synchronization process. The executed protection system has been checked for all fault types taking into account fault resistance, load switching conditions, and the effect of charging currents via using the ATP and MATLAB programs. The results confirmed that the recommended protection has several advantages: high sensitivity, ultra-high speed, and selectivity; it has been influenced by neither fault resistance nor the un-faulted areas. It has also proved successful for both operation modes (i.e. open loop and closed loop). Moreover, in such protection, all loads don’t suffer from supply loss save for loads connected to a faulty busbar, and it is, accordingly, immune to load influence.
AB - A paradigm shift in the philosophy of protection occurs due to distributed generation presence. To adopt the renewable energy generation and enhance supply reliability, a closed-loop operation mode has been involved. The conventional protection cannot adopt the distributed generation since faults have become bidirectional. This paper introduces an ultra-high-speed blocking based on pilot protection system for closed-loop underground cable networks. The proposed protection system uses directional relays based on a suggested averaging window technique and remote terminal units, RTUs, in the automation system. Selection and isolation of the fault zone can be obtained by the neighboring RTUs collaboration. RTUs can automatically be synchronized after fault triggering and don’t require further synchronization process. The executed protection system has been checked for all fault types taking into account fault resistance, load switching conditions, and the effect of charging currents via using the ATP and MATLAB programs. The results confirmed that the recommended protection has several advantages: high sensitivity, ultra-high speed, and selectivity; it has been influenced by neither fault resistance nor the un-faulted areas. It has also proved successful for both operation modes (i.e. open loop and closed loop). Moreover, in such protection, all loads don’t suffer from supply loss save for loads connected to a faulty busbar, and it is, accordingly, immune to load influence.
KW - Automation system
KW - Averaging window
KW - Blocking based protection
KW - Digital closed-loop grid
UR - http://www.scopus.com/inward/record.url?scp=85067817219&partnerID=8YFLogxK
U2 - 10.15866/iree.v14i1.16524
DO - 10.15866/iree.v14i1.16524
M3 - Article
AN - SCOPUS:85067817219
SN - 1827-6660
VL - 14
SP - 43
EP - 54
JO - International Review of Electrical Engineering
JF - International Review of Electrical Engineering
IS - 1
ER -