TY - JOUR
T1 - Multiobjective optimization of a cogeneration system based on gas turbine, organic rankine cycle and double-effect absorbtion chiller
AU - Hai, Tao
AU - Alsubai, Shtwai
AU - Yahya, Rebaz Othman
AU - Gemeay, Entesar
AU - Sharma, Kamal
AU - Alqahtani, Abdullah
AU - Alanazi, Abed
N1 - Publisher Copyright:
© 2023 Elsevier Ltd
PY - 2023/10
Y1 - 2023/10
N2 - Combined cooling, heating and power (CCHP) is one of methods for enhancing the efficiency of the energy conversion systems. In this study a CCHP system consisting of a gas turbin (GT) as the topping cycle, and an organic Rankine cycle (ORC) associated with double-effect absorbtion chiller (DEACH) is decisioned as the bottoming cycle to recover the waste heat from GT exhaust gas. The considered CCHP system is investigated to maintain electricity, heating and cooling demand of a town. A parametric study is investigated and the effect decision variables on the performance indicators including exergy efficiency, total cost rate (TCR), cooling capacity, and ORC power generation is examined. Decision variables of the ORC system consist of HRVG pressure, and condenser pressure and the DEACH including evaporator pressure, condseser pressure, concentration of the concentrated solution, concentration of the weak solution, and solution mass flow rate. Finally a multi-objective optimization performed using Genetic Algorithm (GA) and the optimal design point is selected. It is observed at the optimum point the exergy efficiency, TCR, and sustainability index are 17.56%, 74.49 $/h, and 1.21, respectively.
AB - Combined cooling, heating and power (CCHP) is one of methods for enhancing the efficiency of the energy conversion systems. In this study a CCHP system consisting of a gas turbin (GT) as the topping cycle, and an organic Rankine cycle (ORC) associated with double-effect absorbtion chiller (DEACH) is decisioned as the bottoming cycle to recover the waste heat from GT exhaust gas. The considered CCHP system is investigated to maintain electricity, heating and cooling demand of a town. A parametric study is investigated and the effect decision variables on the performance indicators including exergy efficiency, total cost rate (TCR), cooling capacity, and ORC power generation is examined. Decision variables of the ORC system consist of HRVG pressure, and condenser pressure and the DEACH including evaporator pressure, condseser pressure, concentration of the concentrated solution, concentration of the weak solution, and solution mass flow rate. Finally a multi-objective optimization performed using Genetic Algorithm (GA) and the optimal design point is selected. It is observed at the optimum point the exergy efficiency, TCR, and sustainability index are 17.56%, 74.49 $/h, and 1.21, respectively.
KW - Double-effect absorbtion chiller
KW - Gas turbine
KW - Optimization
KW - Organic rankine cycle
KW - Pareto front
KW - Sustainability analysis
KW - Waste based energy system
UR - http://www.scopus.com/inward/record.url?scp=85165130426&partnerID=8YFLogxK
U2 - 10.1016/j.chemosphere.2023.139371
DO - 10.1016/j.chemosphere.2023.139371
M3 - Article
C2 - 37442387
AN - SCOPUS:85165130426
SN - 0045-6535
VL - 338
JO - Chemosphere
JF - Chemosphere
M1 - 139371
ER -