TY - JOUR
T1 - Interchangeability of Contemporary Semi-adjustable Articulators Used Over Time
T2 - An In Vitro Study
AU - Ateeq Almalki, Abdulrahman
AU - Kutkut, Noor
AU - Althubaitiy, Ramzi
AU - Robaian, Ali
AU - Alzaharni, Khaled
AU - Anadioti, Evanthia
N1 - Publisher Copyright:
© TheAuthor(s). 2024OpenAccess. This article is distributed under the terms of the Creative Commons Attribution 4.0 International License (https://creativecommons.org/licenses/by-nc/4.0/), which permits unrestricted use, distribution, and non-commercial reproduction in any medium, provided you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made. The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/) applies to the data made available in this article, unless otherwise stated.
PY - 2024
Y1 - 2024
N2 - Aim: The purpose of this study is to investigate the interchangeability of newly acquired, short-term used, and long-term used semi-adjustable articulators. Materials and methods: Metal analogs of partially dentate maxillary and mandibular arches were mounted on twelve semi-adjustable Stratos 300 articulators, divided into three groups based on usage over time: New, short-term used (<2 years), long-term used (>2 years) articulators. Each articulator was calibrated according to manufacturer guidelines, ensuring consistency. Occlusal contact forces were recorded using a T-scan III device with a pressure-mapping sensor. Maximum intercuspation (MIP) contact magnitudes were recorded by two calibrated examiners at 10-second intervals, ensuring reliable data collection across all conditions. Results: In MIP, tooth #9 consistently exhibited the highest contact percentages across all articulator conditions, with percentages of 22.2% in the new articulator, 21.8% in the short-term used articulators, and 21.5% in long-term used articulators, indicating stable contact force distribution. Tooth #12 consistently showed the lowest MIP contact percentages, suggesting minimal occlusal force in this region due to its absence. Contact forces, measured at 10-second intervals, showed no significant differences among the different articulator conditions in MIP (p > 0.01). Conclusion:Within the limitations of this invitrostudy, the calibrated Stratos 300 semi-adjustable articulator maintained superior accuracy over time. Clinical significance: The study confirms that the calibrated Stratos 300 semi-adjustable articulators provide consistent and accurate occlusal measurements over time, regardless of their usage over time.
AB - Aim: The purpose of this study is to investigate the interchangeability of newly acquired, short-term used, and long-term used semi-adjustable articulators. Materials and methods: Metal analogs of partially dentate maxillary and mandibular arches were mounted on twelve semi-adjustable Stratos 300 articulators, divided into three groups based on usage over time: New, short-term used (<2 years), long-term used (>2 years) articulators. Each articulator was calibrated according to manufacturer guidelines, ensuring consistency. Occlusal contact forces were recorded using a T-scan III device with a pressure-mapping sensor. Maximum intercuspation (MIP) contact magnitudes were recorded by two calibrated examiners at 10-second intervals, ensuring reliable data collection across all conditions. Results: In MIP, tooth #9 consistently exhibited the highest contact percentages across all articulator conditions, with percentages of 22.2% in the new articulator, 21.8% in the short-term used articulators, and 21.5% in long-term used articulators, indicating stable contact force distribution. Tooth #12 consistently showed the lowest MIP contact percentages, suggesting minimal occlusal force in this region due to its absence. Contact forces, measured at 10-second intervals, showed no significant differences among the different articulator conditions in MIP (p > 0.01). Conclusion:Within the limitations of this invitrostudy, the calibrated Stratos 300 semi-adjustable articulator maintained superior accuracy over time. Clinical significance: The study confirms that the calibrated Stratos 300 semi-adjustable articulators provide consistent and accurate occlusal measurements over time, regardless of their usage over time.
KW - Articulators
KW - Interchangeability
KW - Semi adjustable articulators
UR - http://www.scopus.com/inward/record.url?scp=85214879974&partnerID=8YFLogxK
U2 - 10.5005/jp-journals-10024-3752
DO - 10.5005/jp-journals-10024-3752
M3 - Article
C2 - 39791415
AN - SCOPUS:85214879974
SN - 1526-3711
VL - 25
SP - 869
EP - 872
JO - Journal of Contemporary Dental Practice
JF - Journal of Contemporary Dental Practice
IS - 9
ER -