TY - GEN
T1 - Hydraulic conductivity of trench backfills as a mitigation strategy for chloride-induced corrosion in coastal iron pipelines
AU - Issmaeel, E.
AU - Harris, C.
AU - Gabr, M.
AU - Pourghaz, M.
AU - Lucier, G.
AU - Almuaythir, S.
N1 - Publisher Copyright:
© 2026 by the American Society of Civil Engineers. All Rights Reserved.
PY - 2026
Y1 - 2026
N2 - Chloride-induced corrosion poses a durability risk to underground metallic pipelines, particularly in coastal regions with elevated groundwater salinity. This study employs 3D numerical modeling to simulate chloride transport under varying trench backfill conditions at a site in Jacksonville, North Carolina. The analysis compares the effects of three scenarios as the pipe trench backfill: a high hydraulic conductivity backfill (k = 3 × 10 cm/s), a low hydraulic conductivity backfill (k = 3 × 10 cm/s), and a flowable fill backfill (k = 1 × 10 cm/s) on chloride migration toward a cast-iron pipe buried 1.8 m below the ground surface. Results demonstrate that the chloride threshold concentration of 30 mg/L, associated with the onset of accelerated corrosion, is reached within 190 days in the high-conductivity scenario, but delayed to 790 days with the low-conductivity backfill. In contrast, the threshold is not reached when a flowable fill is used as the pipe trench backfill. These findings highlight the effectiveness of low-conductivity materials as a passive corrosion mitigation strategy, with implications for maintenance and replacement expenses.
AB - Chloride-induced corrosion poses a durability risk to underground metallic pipelines, particularly in coastal regions with elevated groundwater salinity. This study employs 3D numerical modeling to simulate chloride transport under varying trench backfill conditions at a site in Jacksonville, North Carolina. The analysis compares the effects of three scenarios as the pipe trench backfill: a high hydraulic conductivity backfill (k = 3 × 10 cm/s), a low hydraulic conductivity backfill (k = 3 × 10 cm/s), and a flowable fill backfill (k = 1 × 10 cm/s) on chloride migration toward a cast-iron pipe buried 1.8 m below the ground surface. Results demonstrate that the chloride threshold concentration of 30 mg/L, associated with the onset of accelerated corrosion, is reached within 190 days in the high-conductivity scenario, but delayed to 790 days with the low-conductivity backfill. In contrast, the threshold is not reached when a flowable fill is used as the pipe trench backfill. These findings highlight the effectiveness of low-conductivity materials as a passive corrosion mitigation strategy, with implications for maintenance and replacement expenses.
UR - https://www.scopus.com/pages/publications/105041768111
U2 - 10.1061/9780784486757.004
DO - 10.1061/9780784486757.004
M3 - Conference contribution
AN - SCOPUS:105041768111
T3 - Geo-Congress 2026: Geoenvironmental Engineering, Sustainability, and Coastal Geotechnics - Selected papers from Geo-Congress 2026
SP - 28
EP - 37
BT - Geo-Congress 2026
A2 - Montgomery, Jack
A2 - Cox, Brady R.
PB - American Society of Civil Engineers (ASCE)
T2 - Geo-Congress 2026: Geoenvironmental Engineering, Sustainability, and Coastal Geotechnics
Y2 - 9 March 2026 through 12 March 2026
ER -