Skip to main navigation Skip to search Skip to main content

High throughput μ-SPE based elution coupled with UPLC–MS/MS for determination of eluxadoline in plasma sample: Application in pharmacokinetic characterization of PLGA nanoparticle formulations in rats

  • Muzaffar Iqbal
  • , Essam Ezzeldin
  • , Khalid A. Al-Rashood
  • , Ramadan Al-Shdefat
  • , Md Khalid Anwer
  • King Saud University
  • Jadara University

Research output: Contribution to journal › Article › peer-review

11 Scopus citations

Abstract

Eluxadoline is a novel μ- and κ-opioid receptor (OR) agonist and δ-OR antagonist, recently approved as a first line therapy for the treatment of irritable bowel syndrome. Due to abuse potential, poor bioavailability and high intersubject variability, a sensitive and reliable assay is prerequisite for its determination in biological samples. This work first time report the development and validation of UPLC–MS/MS assay for determination of eluxadoline in rat plasma sample using risperidone as an internal standard (IS). A high-throughput 96-well plate format μ-SPE technique was used for plasma sample extraction. The extracted samples were separated on Acquity BEH™ C18 column (100 × 2.1 mm, 1.7 μm) using mobile phase elution of acetonitrile: 20 mM ammonium acetate (80:20, v/v) at a flow rate of 0.3 mL min−1. The precursor to product ion transition of m/z 570.16 → 118.12 (qualifier), 570.16 → 171.08 (quantifier) for eluxadoline, and m/z 411.18 → 191.07 for IS were used for MRM monitoring. The calibration curves were linear in concentration range of 0.15–50 ngmL−1 with LOD and LOQ of 0.07 and 0.15 ngmL−1, respectively. The validation results satisfied the criteria of USFDA and SWGTOX guidelines and were within the acceptable limit. Finally, the method was successfully applied in bioavailability enhancement study of the newly developed PLGA nanoparticles and Eudragit coated PLGA nanoparticles of eluxadoline in rats.

Original languageEnglish
Pages (from-to)172-178
Number of pages7
JournalJournal of Pharmaceutical and Biomedical Analysis
Volume149
DOIs
StatePublished - 5 Feb 2018

Keywords

  • Bioavailability
  • Eluxadoline
  • SWGTOX
  • UPLC–MS/MS
  • μ-SPE

Fingerprint

Dive into the research topics of 'High throughput μ-SPE based elution coupled with UPLC–MS/MS for determination of eluxadoline in plasma sample: Application in pharmacokinetic characterization of PLGA nanoparticle formulations in rats'. Together they form a unique fingerprint.

Cite this