Evaluation of Peri-Implant Parameters and Functional Outcome of Immediately Placed and Loaded Mandibular Overdentures: A 5-year Follow-up Study

Abdulaziz A. AlHelal, Abdulaziz A. Alzaid, Saad H. Almujel, Mohammed Alsaloum, Khalid K. Alanazi, Ramzi O. Althubaitiy, Khulud A. Al-Aali

Research output: Contribution to journalArticlepeer-review

4 Scopus citations

Abstract

Purpose: To evaluate the peri-implant parameters of immediately placed and loaded mandibular overdentures over a 5-year follow-up period. Materials and Methods: All subjects who had been advised and planned for two-implant mandibular overdenture treatment were included in this study. The peri-implant parameters –including plaque index (PI), bleeding index (BI) and peri-implant pocket depth (PIPD) as well as marginal bone loss (MBL) – were assessed. In addition, prosthodontic parameters including abutment-, implant- and denture-related complications were assessed. Patients were evaluated at follow-up visits, scheduled at 1, 12, 24, 36, 48, and 60 months. The data distribution was analysed with the Shapiro-Wilk test. Data within follow-up categories were compared using ANOVA and the Tukey-Kramer test. A p-value < 0.05 was considered sta- tistically significant. Results: Among the 32 participants, 19 were males and 13 were females, with a mean age of 60.5 ± 7.33. The mean plaque index (PI), bleeding index (BI) and peri-implant pocket depth (PIPD) varied over time. However, no statistically significant difference was observed in the plaque index, bleeding index and peri-implant pocket depth over time (p?> 0.05). The mean value at baseline was found to be -0.9 ± 0.3. The values increased over time, with the highest value observed at 60 months 2.6 ± 0.7, which was statistically significant (p < 0.001). Conclusion: Immediately placed and loaded mandibular implant overdentures using two un-splinted implants with loca- tor attachments showed acceptable PI, BI and PIPD at the 5-year follow-up. Statistically significantly greater marginal bone loss was observed from baseline to follow-up, but it was within acceptable limits. A moderate number of restorative and abutment complications were observed during the follow-up of IODs.

Original languageEnglish
Pages (from-to)23-30
Number of pages8
JournalOral Health and Preventive Dentistry
Volume22
DOIs
StatePublished - 2024

Keywords

  • dental implants
  • immediate dental implant loading
  • overdentures
  • peri-implantitis

Fingerprint

Dive into the research topics of 'Evaluation of Peri-Implant Parameters and Functional Outcome of Immediately Placed and Loaded Mandibular Overdentures: A 5-year Follow-up Study'. Together they form a unique fingerprint.

Cite this