This study intends to measure the radiation dose to patients and staff during (i) Dynamic Hip Screw (DHS) and (ii) Dynamic Cannula Screw (DCS) and to evaluate entrance surface Air kerma (ESAK) dose and organ doses and effective doses. Calibrated Thermoluminescence dosimeters (TLD-GR200A) were used. The mean patients' doses were 0.46. mGy and 0.07. mGy for DHS and DCS procedures, respectively. The mean staff doses at the thyroid and chest were 4.69. mGy and 1.21. mGy per procedure. The mean organ and effective dose for patients and staff were higher in DHS compared to DCS. Orthopedic surgeons were exposed to unnecessary radiation doses due to the lack of protection measures. The radiation dose per hip procedure is within the safety limit and less than the previous studies.

Original languageEnglish
Pages (from-to)65-69
Number of pages5
JournalApplied Radiation and Isotopes
Volume100
DOIs
StatePublished - Jun 2015

Keywords

  • Occupational exposure
  • Patient dose
  • Radiation dosimetry
  • TLD

Fingerprint

Dive into the research topics of 'Evaluation of occupational and patient radiation doses in orthopedic surgery'. Together they form a unique fingerprint.

Cite this