TY - JOUR
T1 - Enhancing Diagnostic Precision
T2 - A Distribution-Based Compressed Denoising Scheme using Transfer Learning for Noise Reduction in Medical Imaging
AU - Alsubai, Shtwai
AU - Ahmad, Waseem
AU - Anjum, Mohd
AU - Dutta, Ashit Kumar
AU - Shahab, Sana
AU - Genale, Assefa Senbato
N1 - Publisher Copyright:
© 2025 The Author(s). Published by Bentham Science Publisher. The Author(s). This is an open access article distributed under the terms of the Creative Commons Attribution 4.0 International Public License (CC-BY 4.0), a copy of which is available at: https://creativecommons.org/licenses/by/4.0/legalcode. This license permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are credited.
PY - 2025/9/17
Y1 - 2025/9/17
N2 - Introduction: Accurate interpretation of medical images is vital for diagnosis and treatment planning. However, noise in medical imaging significantly hampers this process, leading to potential diagnostic errors. Traditional denoising techniques often require large datasets or compromise diagnostic details. Method: This study proposes a Distribution-based Compressed Denoising Scheme (DCDS) leveraging transfer learning to enhance diagnostic precision. The framework analyzes pixel distributions to distinguish normal and noisy pixels using incremental and decremental distribution verification. A chest CT scan dataset with Gaussian-like noise was used to train the model, employing correlation mapping between training and target images for effective variance estimation. Result: Experimental analysis showed that DCDS significantly improves noise reduction, variance detection, and diagnostic precision. The peak signal-to-noise ratio improved across all evaluated ranges (24–32 dB), with a noise reduction rate exceeding 82% in optimal conditions. DCDS reduced mean error and analysis time, enhancing overall system efficiency. Transfer learning allowed for effective pixel classification and noise prediction with fewer data and computational resources. Discussion: Compared to existing denoising methods, DCDS offers better generalization through statistical modeling and knowledge-sharing between training and learning states. However, current validation is limited to CT imaging with Gaussian noise. Broader modality testing and integration of perceptual and clinical grading metrics are needed. Conclusion: The DCDS framework presents a promising, lightweight, adaptive, and accurate solution for medical image denoising. It holds potential for real-time diagnostic support, but further optimization and clinical validation are necessary to ensure generalizability across diverse imaging modalities and noise types.
AB - Introduction: Accurate interpretation of medical images is vital for diagnosis and treatment planning. However, noise in medical imaging significantly hampers this process, leading to potential diagnostic errors. Traditional denoising techniques often require large datasets or compromise diagnostic details. Method: This study proposes a Distribution-based Compressed Denoising Scheme (DCDS) leveraging transfer learning to enhance diagnostic precision. The framework analyzes pixel distributions to distinguish normal and noisy pixels using incremental and decremental distribution verification. A chest CT scan dataset with Gaussian-like noise was used to train the model, employing correlation mapping between training and target images for effective variance estimation. Result: Experimental analysis showed that DCDS significantly improves noise reduction, variance detection, and diagnostic precision. The peak signal-to-noise ratio improved across all evaluated ranges (24–32 dB), with a noise reduction rate exceeding 82% in optimal conditions. DCDS reduced mean error and analysis time, enhancing overall system efficiency. Transfer learning allowed for effective pixel classification and noise prediction with fewer data and computational resources. Discussion: Compared to existing denoising methods, DCDS offers better generalization through statistical modeling and knowledge-sharing between training and learning states. However, current validation is limited to CT imaging with Gaussian noise. Broader modality testing and integration of perceptual and clinical grading metrics are needed. Conclusion: The DCDS framework presents a promising, lightweight, adaptive, and accurate solution for medical image denoising. It holds potential for real-time diagnostic support, but further optimization and clinical validation are necessary to ensure generalizability across diverse imaging modalities and noise types.
KW - Compressed denoising scheme
KW - Healthcare diagnosis precision
KW - Medical imaging technology
KW - Noise reduction
KW - Transfer learning
UR - https://www.scopus.com/pages/publications/105017706465
U2 - 10.2174/0115734056391923250827170359
DO - 10.2174/0115734056391923250827170359
M3 - Article
C2 - 40968426
AN - SCOPUS:105017706465
SN - 1573-4056
VL - 21
JO - Current Medical Imaging
JF - Current Medical Imaging
M1 - E15734056391923
ER -