TY - JOUR
T1 - Deep learning-based multi-class classification of thyroid disorders on Tc-99m scintigraphy using modified DenseNet-201
AU - Ghani, Hafiz Muhammad Usman
AU - Khan, Javed
AU - Khan, Naimat Ullah
AU - Khan, Zahid Ullah
AU - Khan, Sajid Ullah
AU - Alturki, Nazik
AU - Awasthi, Shantanu
AU - Ayouni, Sarra
N1 - Publisher Copyright:
© The Author(s) 2026. This article is distributed under the terms of the Creative Commons Attribution-NonCommercial 4.0 License (https://creativecommons.org/licenses/by-nc/4.0/) which permits non-commercial use, reproduction and distribution of the work without further permission provided the original work is attributed as specified on the SAGE and Open Access page (https://us.sagepub.com/en-us/nam/open-access-at-sage).
PY - 2026/1/1
Y1 - 2026/1/1
N2 - Objective: The thyroid gland plays a vital role in human body functions, including metabolism, and any dysfunction of the organ may exacerbate health risks. Early recovery from these conditions depends on the accurate diagnosis of accurate type of thyroid gland disorder. This study aims to develop an automated system for assisting physicians in clinical diagnosis of thyroid gland disorders. Method: The transfer learning capability of the deep neural network model DenseNet-201 was leveraged, and the model was tailored by altering its fully connected layer and the classification layer for the classification of thyroid gland conditions into seven categories, namely cold nodule, hot nodule, multi-nodular goiter, nodular goiter, thyroiditis, toxic diffuse goiter and normal. Results: The class-wise and overall performance of the method was evaluated by computing quantitative metrics like accuracy, specificity, precision, sensitivity, F1-score, and area under the curve (AUC). The degree of similarity between the true labels of thyroid disorders annotated by experts and those predicted by the method was gauged using the kappa coefficient. For the five-fold cross-validated experimental results, we obtained an accuracy of 91.48 ± 2.79%, specificity of 98.58 ± 0.47%, precision of 91.57 ± 2.76%, sensitivity of 91.48 ± 2.77%, F1-score of 91.38 ± 2.82%, and AUC of 0.988 ± 0.006. Additionally, the degree of similarity in the diagnostic capability of the proposed method and medical experts was measured by computing the kappa coefficient as 0.9148. Conclusion: The experimental results of the proposed method were compared with contemporary methods and illustrate relatively better performance in terms of accuracy, sensitivity, precision, and F1-score. The value of the kappa coefficient, 0.9148, also depicts that the proposed method has the potential for applicability in clinical diagnosis to assist physicians in assessing the accurate type of thyroid disorders.
AB - Objective: The thyroid gland plays a vital role in human body functions, including metabolism, and any dysfunction of the organ may exacerbate health risks. Early recovery from these conditions depends on the accurate diagnosis of accurate type of thyroid gland disorder. This study aims to develop an automated system for assisting physicians in clinical diagnosis of thyroid gland disorders. Method: The transfer learning capability of the deep neural network model DenseNet-201 was leveraged, and the model was tailored by altering its fully connected layer and the classification layer for the classification of thyroid gland conditions into seven categories, namely cold nodule, hot nodule, multi-nodular goiter, nodular goiter, thyroiditis, toxic diffuse goiter and normal. Results: The class-wise and overall performance of the method was evaluated by computing quantitative metrics like accuracy, specificity, precision, sensitivity, F1-score, and area under the curve (AUC). The degree of similarity between the true labels of thyroid disorders annotated by experts and those predicted by the method was gauged using the kappa coefficient. For the five-fold cross-validated experimental results, we obtained an accuracy of 91.48 ± 2.79%, specificity of 98.58 ± 0.47%, precision of 91.57 ± 2.76%, sensitivity of 91.48 ± 2.77%, F1-score of 91.38 ± 2.82%, and AUC of 0.988 ± 0.006. Additionally, the degree of similarity in the diagnostic capability of the proposed method and medical experts was measured by computing the kappa coefficient as 0.9148. Conclusion: The experimental results of the proposed method were compared with contemporary methods and illustrate relatively better performance in terms of accuracy, sensitivity, precision, and F1-score. The value of the kappa coefficient, 0.9148, also depicts that the proposed method has the potential for applicability in clinical diagnosis to assist physicians in assessing the accurate type of thyroid disorders.
KW - classification
KW - DenseNet-201
KW - diagnosis
KW - thyroid gland disorders
KW - Thyroid scintigraphy
UR - https://www.scopus.com/pages/publications/105031708223
U2 - 10.1177/20552076261418842
DO - 10.1177/20552076261418842
M3 - Article
AN - SCOPUS:105031708223
SN - 2055-2076
VL - 12
JO - Digital Health
JF - Digital Health
ER -