TY - JOUR
T1 - An Appraisal on Newer Endodontic File Systems
T2 - A Narrative Review
AU - Mustafa, Mohammed
AU - Attur, Kailash
AU - Bagda, Kamal Kumar
AU - Singh, Shalini
AU - Oak, Anjali
AU - Kathiria, Nishtha
N1 - Publisher Copyright:
© The Author(s). 2022 Open Access This article is distributed under the terms of the Creative Commons Attribution 4.0 International License (https://creativecommons.org/licenses/by-nc/4.0/), which permits unrestricted use, distribution, and non-commercial reproduction in any medium, provided you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made. The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/) applies to the data made available in this article, unless otherwise stated
PY - 2022
Y1 - 2022
N2 - Aim: This narrative review aims to explore and elicit the newer endodontic file systems used for root canal treatments. Background: The primary goals of endodontic therapy continue to be the mechanical enlargement and shaping of the intricate endodontic root canal systems to aid in disinfection. Nowadays endodontists have access to a wide range of endodontic file systems for root canal preparations with various design characteristics and benefits. Review results: ProTaper Ultimate (PTU) files’ tip have a triangular convex cross-section, an offset mass of rotating design, a maximum flute diameter of 1.0 mm, and are constructed of gold wire, hence, commonly applied in conditions with restricted accessibility or an extremely curved canal. TruNatomyhas advantages over other cutting-edge file systems like maximum flute diameter of the corona, reduced distance between active cutting flutes, and shorter handles in comparison to SX instruments. In comparison to PTU files, ProTaper Gold (PTG) files are noticeably more elastic and fatigue-resistant. Compared to files in the F1–F3 range, size S1 and S2 files have a significantly longer fatigue life. MicroMega One RECI is more resistant to cyclic fatigue because of its heat treatment and reciprocating action and the C-wire heat treatment of the former gives it flexibility and controlled memory, enabling the prebending of the file. The RECIPROC blue demonstrated enhanced flexibility, increased fatigue resistance, and lower microhardness while maintaining the same surface qualities. Conclusion: As per the necessity and requirement on case to case basis, every endodontic file system has advantages and disadvantages as mentioned in this narrative review. According to the need, an endodontist can select the file system which is required specifically. Although several studies are comparing these various systems in the literature, this narrative review aims to give the clinician a summary of some recently launched endodontic rotary file systems available in the market and their clinical uses.
AB - Aim: This narrative review aims to explore and elicit the newer endodontic file systems used for root canal treatments. Background: The primary goals of endodontic therapy continue to be the mechanical enlargement and shaping of the intricate endodontic root canal systems to aid in disinfection. Nowadays endodontists have access to a wide range of endodontic file systems for root canal preparations with various design characteristics and benefits. Review results: ProTaper Ultimate (PTU) files’ tip have a triangular convex cross-section, an offset mass of rotating design, a maximum flute diameter of 1.0 mm, and are constructed of gold wire, hence, commonly applied in conditions with restricted accessibility or an extremely curved canal. TruNatomyhas advantages over other cutting-edge file systems like maximum flute diameter of the corona, reduced distance between active cutting flutes, and shorter handles in comparison to SX instruments. In comparison to PTU files, ProTaper Gold (PTG) files are noticeably more elastic and fatigue-resistant. Compared to files in the F1–F3 range, size S1 and S2 files have a significantly longer fatigue life. MicroMega One RECI is more resistant to cyclic fatigue because of its heat treatment and reciprocating action and the C-wire heat treatment of the former gives it flexibility and controlled memory, enabling the prebending of the file. The RECIPROC blue demonstrated enhanced flexibility, increased fatigue resistance, and lower microhardness while maintaining the same surface qualities. Conclusion: As per the necessity and requirement on case to case basis, every endodontic file system has advantages and disadvantages as mentioned in this narrative review. According to the need, an endodontist can select the file system which is required specifically. Although several studies are comparing these various systems in the literature, this narrative review aims to give the clinician a summary of some recently launched endodontic rotary file systems available in the market and their clinical uses.
KW - MicroMega One RECI
KW - ProTaper Gold
KW - ProTpaer Ultimate
KW - RECIPROC blue
KW - TruNatomy
UR - http://www.scopus.com/inward/record.url?scp=85148205147&partnerID=8YFLogxK
U2 - 10.5005/jp-journals-10024-3398
DO - 10.5005/jp-journals-10024-3398
M3 - Review article
C2 - 37283003
AN - SCOPUS:85148205147
SN - 1526-3711
VL - 23
SP - 944
EP - 952
JO - Journal of Contemporary Dental Practice
JF - Journal of Contemporary Dental Practice
IS - 9
ER -