T1 - Second law efficiency analysis of air injection into inner tube of double tube heat exchanger
AU - Sinaga, Nazaruddin
AU - khorasani, Saleh
AU - Sooppy Nisar, Kottakkaran
AU - Kaood, Amr
N1 - Publisher Copyright:
© 2020 THE AUTHORS
PY - 2021/2
Y1 - 2021/2
N2 - At present study, thermal performance of a double tube heat exchanger due to stream of air/water two phase flow through inner tube is experimentally studied. Air and hot water were mixed in a T-junction outside heat exchanger and then were followed into inner tube of heat exchanger. Told water flow rate was kept constant and was equal to 2 lit/min. For hot water flow rate, four different flow rates of 3, 4, 5 and 6 lit/min was considered. Also inlet temperature of cold and hot water streams were almost constant and were within range of 17–19 °C and 48–50 °C. Also, for air flow rate five different flow rates of 1, 2, 3, 4 and 5 lit/min were considered. Volume fraction was within the range of 0.14 and 0.62. Obtained results were analyzed based on several energetic and exergitic parameters including pressure drop, effectiveness, Number of Transfer Units, heat transfer coefficient, dimensionless exergy loss and Witte-Shamsundar efficiency factor. Results presented an increment of 33% and 38% in heat transfer coefficient and Number of Transfer Units, respectively. Maximum value of Witte-Shamsundar efficiency factor was found to be 0.973 and was related to Volume fraction of 0.57 and has occurred at counter flow.
AB - At present study, thermal performance of a double tube heat exchanger due to stream of air/water two phase flow through inner tube is experimentally studied. Air and hot water were mixed in a T-junction outside heat exchanger and then were followed into inner tube of heat exchanger. Told water flow rate was kept constant and was equal to 2 lit/min. For hot water flow rate, four different flow rates of 3, 4, 5 and 6 lit/min was considered. Also inlet temperature of cold and hot water streams were almost constant and were within range of 17–19 °C and 48–50 °C. Also, for air flow rate five different flow rates of 1, 2, 3, 4 and 5 lit/min were considered. Volume fraction was within the range of 0.14 and 0.62. Obtained results were analyzed based on several energetic and exergitic parameters including pressure drop, effectiveness, Number of Transfer Units, heat transfer coefficient, dimensionless exergy loss and Witte-Shamsundar efficiency factor. Results presented an increment of 33% and 38% in heat transfer coefficient and Number of Transfer Units, respectively. Maximum value of Witte-Shamsundar efficiency factor was found to be 0.973 and was related to Volume fraction of 0.57 and has occurred at counter flow.
KW - Dimensionless exergy loss
KW - Double-tube heat exchanger
KW - Effectiveness-NTU
KW - Overall heat transfer coeffOverall heat transfer coefficient
KW - Two-phase flow
KW - Witte-Shamssundar efficiency (η)
UR - https://www.scopus.com/pages/publications/85097451131
U2 - 10.1016/j.aej.2020.10.064
DO - 10.1016/j.aej.2020.10.064
M3 - Article
AN - SCOPUS:85097451131
SN - 1110-0168
VL - 60
SP - 1465
EP - 1476
JO - Alexandria Engineering Journal
JF - Alexandria Engineering Journal
IS - 1
ER -