Patient Exposure during Fluoroscopy-guided Pacemaker Implantation Procedures

  • M. Alkhorayef
  • , A. Sulieman
  • , E. Babikir
  • , E. Daar
  • , M. Alnaaimi
  • , M. Alduaij
  • , D. Bradley

Research output: Contribution to journalArticlepeer-review

7 Scopus citations

Abstract

A pacemaker, which is used for heart resynchronization with electrical impulses, is used to manage many clinical conditions. Recently, the frequency of pacemaker implantation procedures has increased to more than 50% worldwide. During this procedure, patients can be exposed to excessive radiation exposure. Wide range of doses has been reported in previous studies, suggesting that optimization of this procedure has not been fulfilled yet. The current study evaluated patient radiation exposure during cardiac pacemaker procedures and quantified the patient effective dose. A total of 145 procedures were performed for five pacemaker procedures (VVI, VVIR, VVD, VVDR, and DDDR) at two hospitals. Patient doses were measured using the kerma-area product meter. Effective doses were estimated using software based on Monte Carlo simulation from the National Radiological Protection Board (NRPB, now The Health Protection Agency). The effective dose values were used to estimate cancer risk from the pacemaker procedure. Patient demographic data and exposure parameters for fluoroscopy and radiography were quantified. The mean patient doses ± SD per procedure (Gy cm2) for VVI, VVIR, VVD, VVDR, and DDDR were 1.52 ± 0.13 (1.43–1.61), 3.28 ± 2.34 (0.29–8.73), 3.04 ± 1.67 (1.57–4.86), 6.04 ± 2.326 3.29–8.58), and 8.8 ± 3.6 (4.5–26.20), respectively. The overall patient effective dose was 1.1 mSv per procedure. It is obvious that the DDDR procedure exposed patients to the highest radiation dose. Patient dose variation can be attributed to procedure type, exposure parameter settings, and fluoroscopy time. The results of this study showed that patient doses during different pacemaker procedures are lower compared to previous reported values. Patient risk from pacemaker procedure is low, compared to other cardiac interventional procedures. Patients’ exposures were mainly influenced by the type of procedures and the clinical indication.

Original languageEnglish
Pages (from-to)14-17
Number of pages4
JournalApplied Radiation and Isotopes
Volume138
DOIs
StatePublished - Aug 2018

UN SDGs

This output contributes to the following UN Sustainable Development Goals (SDGs)

  1. SDG 3 - Good Health and Well-being
    SDG 3 Good Health and Well-being

Keywords

  • Effective dose
  • Interventional radiology
  • Medical exposure
  • Pacemaker
  • Radiation dosimetry

Fingerprint

Dive into the research topics of 'Patient Exposure during Fluoroscopy-guided Pacemaker Implantation Procedures'. Together they form a unique fingerprint.

Cite this